top of page
562 - 625 Range
Application data
Output Ratings
480/277 V
440/254 V
380/220 V
240/139 V
240/120 V
220/127 V
220/110 V
208/120 V
Prime
Standby
kVA
kW
kVA
kW
900
720
1000
800
900
720
1000
800
720
720
1000
796.4
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Engine Technical Data
No. of Cylinders
Alignment
Cycle
Bore
Stroke (mm)
Induction
Cooling Method
Governing Type
Governing Class
Compression Ratio
Displacement (L)
Turbocharged
Electronic
8
Moment of Inertia (Kg/m²)
Dimensions
Length (mm)
Width (mm)
Height (mm)
Weight (Dry, Kg)
Weight (Wet, Kg)
4788
2046
2419
7201
Voltage
Ground
Battery Charger Amps
Engine Weight Dry (Kg)
Engine Weight Wet (Kg)
3428
Ratings and Performance Data
Engine Performance Data
Phase
Engine Make
Engine Model
Three
Engine Speed
Perkins
4008TAG1
Gross Engine Power (kW)
Prime
Standby
0
0
Alternator Make
Leroy Somer
BMEP (kPa)
Alternator Model
Option1
Control Panel
Option1
Option2
Option3
1002.2
Deep Sea 7410
Option4
Base Frame
Circuit Breaker Type
Frequency (Hz)
Options Available
60
Engine Speed (rpm)
Fuel Tank Capacity (L)
Fuel Consumption Prime (liters/hr)
Fuel Consumption Standby (liters/hr)
-
Fuel System
Fuel Filter Type
Eco Replaceable Element
Recommended Fuel
Class A2 Diesel
Fuel Consumption at
110%
100%
75%
50%
Prime (l/hr)
198.3
147.1
102.6
Standby (l/hr)
223.2
112
163.4
Air System
Air Filter Type
Replaceable Element
Combustion Air Flow Prime (m³/min)
Combustion Air Flow Standby (m³/min)
Max. Combustion Air Intake Restriction (kPa)
72
74
3.7
Alternator Physical Data
Cooling System
Cooling System Capacity (L)
153
Water Pump Type
Centrifugal
Radiator Fan Load (kW)
56
Radiator Cooling Airflow (m³/min)
External Restriction to Cooling Airflow (m³/min)
Heat Rejected to Water & Lube Oil (kW)
Heat Radiation to Room* (kW)
1461
196
307
122
Lubrication System
Oil Filter Type
Spin-On, Full Flow
Total Oil Capacity (L)
166
Oil Pan Capacity (L)
153
Oil Type
API CG4 15W-40
Oil Cooling Method
Water
No. of Bearings
Insulation Class
Winding Pitch
Winding Code
Wires
Ingress Protection Rating
Excitation System
Option1
Option2
Option3
Option4
AVR Model
Option1
Option2
3-Feb
Alternator Performance Data 60 Hz
Exhaust System
Maximum Allowable Back Pressure
Prime
Exhaust Gas Flow (m³/min)
207
Exhaust Gas Temperature (m³/min)
460
10.7
Standby
207
490
Alternator Operating Data
Overspeed (rpm)
Voltage Regulation (Steady State, %)
2250
+/-0.5
Wave Form NEMA = TIF
Wave Form IEC = THF (%)
50
2
Total Harmonic content LL/LN (%)
4
Radio Interference
EN61000-6
Radiant Heat (kW)
39
Voltage
*MSC (kVA)
**SSC (%)
***Xd
***X'd
***X''d
480/277 V
440/254 V
380/220 V
3128
300
2029
300
2667
300
2.447
0.117
2.912
0.139
0.094
0.111
3.905
0.187
0.146
240/139 V
-
-
-
-
-
240/120 V
220/127 V
220/110 V
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
208/120 V
-
-
-
-
-
*Motor Starting Capability
**Short Circuit Capacity
***Reactances
bottom of page